TDE Series Ultra-Low Temperature Freezers [TDE60086FA] -86C, 600 Box Capacity , 115V/60Hz
Performance
- Powered by H-drive's hydrocarbon technology, these systems save up to 25% in energy usage and heat rejection over conventional refrigerant ultra-low freezers1
- Designed for daily usage, recovers cabinet temperature 20% faster after opening the door.2
- A quiet sound output below 53 dBA, enables the freezer to come out of the hallway and into the lab
- Meets +/-10°C validation protocols at -80°C with strong peak variation and steady-state temperature variation
- Natural hydrocarbon refrigerants reduce system operating stresses promoting outstanding reliability and worry-free sample protection
User Friendly
- The H-drive Information Center (HIC) combines easy to read temperature with simple capacitive touch buttons in a 5.6” display
- Four capacities (300, 400, 500 and 600 2-inch box) to accommodate a variety of storage needs and lab footprint specifications
- All models contain four inner doors allowing for easy sample access without exposing greater freezer content to ambient conditions
- Improved customer convenience with new ergonomically designed handle, high contrast eye-level display, and comfortable easy-access shelf locations.
- Compatible with most racking systems including a full range of Thermo Scientific™ racks for boxes, microplates, Thermo Scientific™ Matrix™ and Nunc CryoBank™ tubes
- Security features including alarm settings and padlock-compatible doors
Sustainability
- Manufactured in an award-winning, zero-waste to landfill facility
- Lower HVAC costs as a result of less heat emission into the environment
- Natural refrigerants and water-blown foam insulation, making the Series compliant with the U.S. Environmental Protection Agency’s Significant New Alternatives Policy (SNAP), the European Union’s F-Gas and other sustainability standards
Footnotes:
- Internal data comparing 11.2 kWh/day to UXF600 = 14.9 kWh/day. Data on file.
- Typical freezer test data based on internal testing in ambient temperature at 20°C; Typical standard validation protocol of +/-10°C.
Specifications | |
---|---|
Green Features | Energy Efficient |
Product Line | Thermo Scientific |
Compressor | H-Drive Compressor |
Door Style | 1 Outer, 4 Inner |
Holds | 2 in. Boxes (600) |
Insulation | Vacuum Insulation Panels (VIP) + Water-Blown Polyurethane Foam (SNAP-compliant) |
Material | Polyurethane Foam (Insulation), Stainless Steel (Interior) |
Monitoring Options | Alarm, Recorder |
No. of Doors | 1 |
Rack Capacity | 12 |
Shelves | 3 |
Style | Upright |
Description | Thermo Scientific TDE Series Ultra-Low Freezers, 600-Box Capacity, 115V, 60Hz |
Temperature Range | -50°C to -86°C |
Certifications/Compliance | cULus |
Capacity (English) | 28.8 cu. ft. |
Capacity (Metric) | 816 L |
Vial Capacity | 60,000 x 2mL |
Electrical Requirements | 115 V 60 Hz |
Voltage | 115 V |
Frequency | 60 Hz |
Amperage | 12.7/20 A |
Plug Type | NEMA 5-20 |
Dimensions (D x W x H) Interior | 28.3 x 34.4 x 51.2 in. (71.9 x 87.3 x 130.1 cm) |
Weight (English) | 709 lb. |
Weight (Metric) | 322 kg |
Shipping Weight (English) | 820 lb. |
Shipping Weight (Metric) | 372 kg |
Display | HIC 5.6 in. 7-segment display with capacitive touch buttons |
Refrigerant | R290 (1st stage), R170 + R290 mix (2nd stage) |
Capacity (English) Shelf | 245 lb. |
Capacity (Metric) Shelf | 111 kg |
Smart View Compatibility | Smart-Vue Compatible |
Warranty | Warranty varies by country, please contact us for details |
Inner Doors | 4 |
Setpoint Security | Yes |
Defrost | Manual |
Connectivity | External Monitoring/Cloud Compatible; 4-20mA, RS485, Dry Contacts |
Dimensions (DxWxH) Exterior | 38.5 x 39.6 x 78 in. (97.7 x 100.6 x 198.1 cm) |
Type | Ultra-Low Freezer, Upright |
Unit Size | Each |
Voltage | 115 V 60 Hz |
---|
BEFORE YOU PURCHASE...RESEARCH!
We encourage you to explore the wealth of information available on our product pages. To ensure you're making the right choice, please:
- Review the product specifications.
- Consult with the manufacturer or
- Get in touch with our dedicated sales and technical teams.
To ensure a seamless experience for all, we acept returns for new items. All returns are subject to a 20% restocking fee. Please double-check that the equipment you're selecting meets your requirements.
DAMAGED SHIPMENTS
When your order arrives, we recommend a thorough check for any potential damage before finalizing the delivery process:
- Before signing any delivery documentation, ensure your equipment is in perfect condition.
- If you spot any damage, kindly decline the delivery, and make a note of the damage on the Bill of Lading. Alternatively, inform the UPS/Fedex driver so they can document the reason.
If there are any concerns, please contact us within 48 hours of receipt. If damage is discovered after accepting the delivery without prior documentation, please address any claims directly with the delivery carrier.
RETURNS & WARRANTY
Should you encounter any issues with your instrument that can't be addressed, you may return it within 30 days. Please note that certain products are subject to a 20% restocking fee. Customized items are final sale and ineligible for return. When we receive returned items, they undergo a comprehensive inspection and testing. We retain the right to decline returns for items that have been mishandled or improperly used.