MaxQ™ 8000 Incubated/Refrigerated Stackable Shakers - INCUBATED SHAKER, 120V
- Three times the capacity of a floor shaker in virtually the same footprint
- Built for both sensitive eukaryotic culture applications—with contamination-reducing HEPA filtration, coved corner design, single-piece chamber and tight temperature uniformity—and for demanding prokaryotic culture applications
- Rugged construction, wide speed range and no limits on “hard shake” speed, even when stacked three-high
Microprocessor Control/Monitoring System:
- Run and setpoints displayed simultaneously
- Tracks total accumulated time on motor and drive systems
- Audible/visual over- and undertemperature tracking alarms ensure product protection
- Separate adjustable overtemperature safety alarm with independent probe provides additional backup on heated units
- Audible/visual, high/low rpm tracking alarms alert to speed deviations
- Alarms can be silenced temporarily and ring back as a reminder of unresolved alarm conditions
- Remote alarm contacts for convenient monitoring from another location
- Nonvolatile memory saves settings during a power outage and automatically restarts the unit after power is restored
- RS-232 port is standard and permits computer interface and monitoring of time, temperature and speed
- Controlled acceleration circuitry provides smooth start-up and stopping to eliminate splashing and wetting of flask closures
- Functions can be calibrated easily through the keypad and sealed control panel
Control Panel:
- Backlit two-line, 40-character LCD alphanumeric display of actual (run) and setpoint parameters and alarm condition
- Icons/buttons allow easy programming of set parameters
- Time: Counts upward, showing total operating hours and minutes for the run
- Speed: Displays the actual platform speed (rpm) and speed set points
- Temp C: Displays the actual temperature inside the chamber and temperature set points
Construction:
- Electronic components and HEPA filter easily accessed from the front during regular maintenance or service
- Flip-down handle/latch on quick-release base (included) prevents shaker from running if platform is not secured
- Insulated, fold-down door with slide-out platform provides 100% sample access
- Wide-view window and xenon light provide high visibility for harvesting
- Top platform height is under 61 in. (154.9cm) when units are stacked three high
- Heavy-gauge cold-rolled steel exterior
- Type 304 stainless-steel chamber with coved corners and built-in drain; holds 2L Erlenmeyer flasks, has xenon light with switch
- Magnetic door gasket for tight seal
- Stacking kit is included with each shaker at no additional cost
Mechanics
- Heavy-duty, eccentric drive mechanism allows extended speed ranges from 25 to 400rpm ±1rpm with minimal vibration, even when shakers are stacked three high
- Durable, dynamically balanced orbital shaker mechanism ensures optimum oxygenation and nutrient mixing, reduced cell clumping, and prevention of splashing and flask wetting
- Triple counterbalanced mechanism provides optimum handling of full or unbalanced loads, regardless of flask placement
- Cool-running, brushless, 1/3hp DC motor ensures continuous maintenance-free operation
- Forced laminar airflow through the HEPA filter provides excellent temperature uniformity, reduces risk of cross-contamination
Ordering Information:
Platform not included. Optional single and double shaker stands and freestanding chart recorder is available.
Includes:
Stacking kit with each shaker.
Requires:
Dedicated or universal slideout shaker platform 29.5 × 18 in. (74.9 × 45.7cm), available separately.
Recommended for:
- Bacterial suspensions
- Hybridizations
- Solubility studies
- Diagnostic test
- Extraction procedures
- Washing procedures
- General mixing
- Protein expression
- Staining and destaining
- Plasmid purification
Specifications | |
---|---|
Model | MaxQ 8000 |
Speed Range | 25 to 400 ±1 rpm |
Temperature Range (English) | 50°F to 140°F |
Temperature Range (Metric) | Ambient+10° to 60°C |
Temperature Resolution | ±0.15°C |
Orbit | 2.5cm (1 in.) |
Capacity | Twelve 2L Erlenmeyer flasks |
Control | Digital |
Depth (English) Interior | 23.8 in. |
Depth (Metric) Interior | 60.5cm |
Height (English) Exterior | 25 in. |
Height (English) Interior | 11.8 in. |
Height (Metric) Exterior | 63.5cm |
Height (Metric) Interior | 30cm |
Hertz | 60Hz |
Length (English) Exterior | 33.3 in. |
Length (Metric) Exterior | 84.6cm |
Load Bearing Capacity | 71 lb. (32kg) |
Motor Type | DC brushless |
Shipping Weight (English) | 658 lb. |
Shipping Weight (Metric) | 298.5kg |
Temperature Accuracy | ±0.15°C at 37°C |
Timer | Continuous or timed from 1 min. up to 199 hr. and 59 min |
Width (English) Exterior | 46.5 in. |
Width (English) Interior | 33.4 in. |
Width (Metric) Exterior | 118.1cm |
Width (Metric) Interior | 84.6cm |
Cabinet | Heavy-gauge cold-rolled steel |
Chamber Material | Type 304 stainless steel |
Description | Large Stackable Incubated Orbital Shaker |
Display | LED: Time, Speed, Temperature include run and setpoints |
Item Description | Large Stackable Incubated Orbital Shaker |
Type | Shakers |
Certifications/Compliance | UL, cUL, CE |
Dimensions (L x W x H) Exterior | 33.3 x 46.5 x 25 in. (84.6 x 118.1 x 63.5cm) |
Dimensions (D x W x H) Interior | 23.8 x 33.4 x 11.8 in. (60.5 x 84.6 x 30cm) |
Electrical Requirements | 120V 60Hz |
Speed | 25 to 400 rpm |
Voltage | 120V |
Unit Size | Each |
Voltage | 120V 60Hz |
---|
BEFORE YOU PURCHASE...RESEARCH!
We encourage you to explore the wealth of information available on our product pages. To ensure you're making the right choice, please:
- Review the product specifications.
- Consult with the manufacturer or
- Get in touch with our dedicated sales and technical teams.
To ensure a seamless experience for all, we acept returns for new items. All returns are subject to a 20% restocking fee. Please double-check that the equipment you're selecting meets your requirements.
DAMAGED SHIPMENTS
When your order arrives, we recommend a thorough check for any potential damage before finalizing the delivery process:
- Before signing any delivery documentation, ensure your equipment is in perfect condition.
- If you spot any damage, kindly decline the delivery, and make a note of the damage on the Bill of Lading. Alternatively, inform the UPS/Fedex driver so they can document the reason.
If there are any concerns, please contact us within 48 hours of receipt. If damage is discovered after accepting the delivery without prior documentation, please address any claims directly with the delivery carrier.
RETURNS & WARRANTY
Should you encounter any issues with your instrument that can't be addressed, you may return it within 30 days. Please note that certain products are subject to a 20% restocking fee. Customized items are final sale and ineligible for return. When we receive returned items, they undergo a comprehensive inspection and testing. We retain the right to decline returns for items that have been mishandled or improperly used.