Barnstead™ GenPure™ xCAD Plus Ultrapure Water Purification System - UV-TOC with Bench Top x-CAD Plus
xCAD (Extended Control and Dispenser):
- System provides more flexibility for ultrapure water dispensing with an action radius of 32 in. (80cm).
- Ergonomic dispensing arm provides precise volume dosing at the press of a button.
- Flexible dispenser offers positions including turned, height adjusted or extended toward your vessel.
- One-of-a-kind design provides access to all system controls at your fingertips.
Simultaneously dispense from up to three dispensers:
- Each system ships with a single xCAD Plus remote dispenser.
- For increased flexibility, add one or two more xCAD Plus dispensers.
Integrated feed water monitoring:
- Additional measuring cell monitors feed water conductivity.
- If the quality of the feed water drops below the set value, a fault message will immediately be displayed.
Online TOC measurement with UV intensity monitoring (available on systems with optional TOC only):
- Real-time TOC monitoring offers continual measurement of organic substances present in the water.
- Continuous monitoring of UV intensity removes the risk of false TOC values due to diminished UV intensity.
- Fault message alerts user when the UV lamp intensity is no longer sufficient for accurate TOC measurements.
UV Photo-oxidation 185/254 nm:
- High performance UV assembly reliably reduces the content of microorganisms and their metabolites.
- UV oxidation also reduces organic compounds in the water to ultra-low levels.
Leak detection:
- An error message is displayed when internal leaks are detected.
Ready to use:
- Feed water pressure switch, wall bracket, UV lamp, ultrapure cartridge, sterile filter, all are included in one part number.
Measurement of conductivity/resistivity:
- Conductivity cells are carefully calibrated prior to each measurement via built-in reference resistance with cell constants at 0.01cm-1.
- Temperature measurements are made by a platinum chip sensor with ± 0.1°C accuracy.
Quick-connect cartridge replacement:
- Aquastop quick-connect capability enables cartridge replacement within seconds even mid-operation.
Exact dosing:
- Electronic dosing yields fully automatic volume control of 0.01-65 L with <2% accuracy.
GLP-compliant documentation:
- Real-time clock and code-protected operating system prevents unauthorized changes to system settings.
- RS-232 interface with adjustable send-interval offers safe data transfer of all measured data, faults, date and time to a PC computer or log printer.
- Digital microprocessor control automatically monitors and stores faults from the last four weeks.
- USP-compliant conductivity measurement with temperature compensation can be switched on or off.
Specifications | |
---|---|
Frequency | 50/60 Hz |
Feedwater Connector | 3/4 in. |
Product Water Type | Type 1 |
TOC Monitor with UV Intensity Monitoring | Yes |
Type | Water Purification System |
Resistivity | 18.2 Mohm.cm at 25°C |
Conductivity | 0.055µS/cm |
Flow Rate | Up to 2 L/min. |
Total Organic Carbon | 1 to 5 ppb |
Bacterial Content | <0.01 CFU/mL |
Particles >0.2µM/mL | <1 |
Remote Dispenser | Yes |
Feed Water Monitoring | Integrated |
Height (English) | 24 in. |
Height (Metric) | 615 mm |
Width (English) | 14.6 in. |
Width (Metric) | 372 mm |
Operating Pressure | 0.1 to 6 bar |
Voltage | 90/240 V |
Temperature Range (Metric) | 2°C to 35°C |
Depth (English) | 13 in. |
Depth (Metric) | 330 mm |
Description | Barnstead GenPure xCAD Plus UV – TOC (bench version) |
Model | Barnstead GenPure xCAD Plus UV - TOC (bench version) |
Power Consumption | 0.1 kW |
Electrical Requirements | 90/240 V 50/60 Hz |
Unit Size | Each |
Voltage | 90/240 V 50/60 Hz |
---|
BEFORE YOU PURCHASE...RESEARCH!
We encourage you to explore the wealth of information available on our product pages. To ensure you're making the right choice, please:
- Review the product specifications.
- Consult with the manufacturer or
- Get in touch with our dedicated sales and technical teams.
To ensure a seamless experience for all, we acept returns for new items. All returns are subject to a 20% restocking fee. Please double-check that the equipment you're selecting meets your requirements.
DAMAGED SHIPMENTS
When your order arrives, we recommend a thorough check for any potential damage before finalizing the delivery process:
- Before signing any delivery documentation, ensure your equipment is in perfect condition.
- If you spot any damage, kindly decline the delivery, and make a note of the damage on the Bill of Lading. Alternatively, inform the UPS/Fedex driver so they can document the reason.
If there are any concerns, please contact us within 48 hours of receipt. If damage is discovered after accepting the delivery without prior documentation, please address any claims directly with the delivery carrier.
RETURNS & WARRANTY
Should you encounter any issues with your instrument that can't be addressed, you may return it within 30 days. Please note that certain products are subject to a 20% restocking fee. Customized items are final sale and ineligible for return. When we receive returned items, they undergo a comprehensive inspection and testing. We retain the right to decline returns for items that have been mishandled or improperly used.